After a recent slight miscalculation with off-the-shelf point motors I started thinking about making my own point motors. How difficult could it be and would it be cheaper?
Having remotely operated working points makes a railway a lot more fun and enjoyable but it’s not cheap. Point motors go for around £7 to £10 each, if you’ve got a fair number of turnouts on your layout that can quickly mount up.
Also, the standard point motors are aren’t the most flexible when it comes to positioning. Surface mounted motors (such as Peco PL11′s or the Hornby equivalent) need to be next to the point while under board motors need to be directly below the point and even with extension pins there’s a hard limit on the depth of the baseboard through which they reach.
I ran into exactly this problem with some Peco PL-10E or PL-10WE point motors recently. They worked find but a couple of the points on my layout where right up against supporting joists on the underside of my baseboard and by the time I’d added the mounting bracket for the motor wouldn’t fit where it was needed.
This was down to my own fault and stupidity and no reflection on the Peco motors which I’d otherwise not had a problem with but it set me thinking.
Could I MacGyver my own point motors from solenoids (electro-magnetics that can be switched on and off and with the magnetism used to move a metal connecting rod)? Doing so would give me more flexibility for their position. Just as importantly, solenoids are available on eBay for around £3. That’s a good saving if they could be made to work.
First things first I ordered a couple of solenoids off eBay. These cost just over £3 each and there are sellers doing bulk packs reducing the unit cost even more but to start with I just went for a couple of 12V units (I went for 12V as these would work with a transformer I had spare).
Then it was just a case of connecting the two wires from the solenoid to a switch and the transformer. A bit of soldering and a quick test run showed the basic motor working giving a pleasing clunk when powered. Applying the switch activated the magnetic pulling the rod in one direction. A spring returned the pole to its original position when unpowered.
The fiddly bit was connecting the rod to the point.
After experimentation, I found some suitable 2mm wire from a craft shop (40 meters for £2.49) that fitted into the hole on the moving tie-bar of the point, was flexible enough to be bent around and secured to the motor rod while also being rigid enough to push and pull the point when the motor operated.
It worked and here’s a quick video showing it in action on part of my workshop layout. When done for real on a layout the wire would be held in place, but loosely so allowing it to move, and disguised as would the solenoid.
The great thing about this DIY point motor, other than the price of course, is that the wire can reach further than the connecting assembly of commercial point motors giving more flexibility as to where the motor can be placed relative the point.
Admittedly, these solenoids are physically larger than the Hornby and Peco products but for under board mounting they’re fine and as they can be positioned further away from the points they can be hidden in nearby buildings or perhaps scenery fixtures if mounted on the surface of the layout.
For full operational use on a layout a capacitor discard unit, such as those from Block Signalling, would be used (as it would for commercial points) to prevent motor burn out and provide a single high current pulse to the point but for this adventure in DIY point motors I’ve let it go. I might revisit this post in future with an update on this aspect.
> A final, personal, note: I spend a huge amount of time testing, photographing, writing and researching techniques for these articles and pay for all the running costs of MRE out of my own pocket. If you found this article useful you can support me by making a donation on my fund-raising page. Thanks and happy modelling, Andy.

Andy is a lifelong modeler, writer, and founder of modelrailwayengineer.com. He has been building model railways, dioramas, and miniatures for over 20 years. His passion for model making and railways began when he was a child, building his first layout at the age of seven.
Andy’s particular passion is making scenery and structures in 4mm scale, which he sells commercially. He is particularly interested in modelling the railways of South West England during the late Victorian/early Edwardian era, although he also enjoys making sci-fi and fantasy figures and dioramas. His website has won several awards, and he is a member of MERG (Model Railway Electronics Group) and the 009 Society.
When not making models, Andy lives in Surrey with his wife and teenage son. Other interests include history, science fiction, photography, and programming. Read more about Andy.
You say that you got your solenoids online at amazon, but what make are they please? As I have 30 points on my fiddle yard they need to be on the surface.
is it possible to use them to fit straight on to the tie bar without any wire in between
As you say, point motors can be expensive. I like this idea. But wiring is not my strong suit. Is there any chance you could put up a diagram showing how to wire them up when used with a CDU? Because you only ever throw one point at a time, you only need 1 CDU to power all your points, right?
I’ll see what I can do re a wiring diagram, until then this link might help: http://www.thehobbyshed.co.uk/capacitor-discharge-unit
You’re correct re needing only one CDU although remember the CDU will need time to store up its charge between uses so if you have multiple points to change quickly – if they’re close to each other for example – you might need more than one.
Andy
Andy, that wiring diagram at thehobbyshed is exactly what i was hoping for, thank you.
I see your point re multiple CDU’s, and could see them being necessary especially during an ops session where multiple operators might be switching points at the same time. Not a scenario I expect to be involved in, but your point remains…and CDU’s are cheap enough. 🙂
I like the idea of solenoids for point control. Have you any suggestions about where to purchase suitable ones for n gauge turnouts.
Thanks
Phil
Hi Phil, if you hide them under the baseboard their physical size doesn’t really matter. I get mine on eBay although they can also be found on online electronics retailers.